Re: Fetching Data in APO - Process Order
Hello Brijesh, Did you try using *OM*ORDER*GET*DATA* function module. Hopefully, it should help you achieve what you're looking fro.Babu Kilari
View ArticleRe: Roles for BI not recognized
Hi Pradeep Not sure where you are at with this but I've given you my perspective. Have you attempted to split the systems to reference different groups as per my suggestion? That is one group for ECC...
View ArticleRe: TCPIP RFC connection test failed between SAP Data Services & SAP BW
Hi Rishi, No, the RFC connection that was created at the DS Admin console does not even started. it was stopped and showing red colour in it status. regards,willie
View ArticleRe: CRM WEB UI Delete Table Filter
Hi Shirkant, DELETE_FILTER does not clear values from result view. It just delete the filter check from collection with which it is filtering the data and will add all data to collection that was not...
View ArticleRe: Two different settings required for an inspection type (HU and Non-HU)
Hello Mr Craig, I never said that you don't need to activate the inspection type with variance 1 for inspection lot generation. That is one mandate thing need to be done. What I said that out of two...
View ArticleRe: How close n notifications by IW32 (TECO order) pop-up?
Hello Please use the User exit -->IWO10004 Maintenance order: Customer check for order completion Or...
View ArticleHR renewal FP4: Substitution functionality and UI5 based MSS
G'day, We are working on a HR Renewal 1.0 FP4 based system. We are using NWBC 4.0 PL5(now that really matters for this issue). We are using UI5 based ESS and MSS. We have configured UI5 based Approval...
View ArticleRe: Error in DFKKKO While Invoicing For Multiple Consumers
Hi Jay, Check SAP Note 1857966. The process that you are following is pretty much standard.So if you are getting an error even after you implement the above SAP Note, I would recommend you to raise an...
View ArticleRe: Delta Init Required for Safety Interval Limit Change?
Hi, 1. Yes, when we pass upper limit, need to reinit, other wise changes won't work for existing init. 2.Yes, You can do init without data transfer. your at safe side as your delta is calday(locking...
View ArticleRe: Approve Timesheet App is not working
I also have the below doubt while configuring approve timesheet app.How do i perform the step 5 as seen in the screenshot below:
View ArticleRe: Java Stack Installation on existing ABAP stack.
Hi Parag Please see this note : 855534 - Dual Stack and SAP Business Suite 7As per the SAP recommendations , new Add in installations are not supported except for PI and Solution manager. You will have...
View ArticleRe: Exception in B2B add-on receiver AS2 adapter with signature
Hi All, Problem was with the bouncy castle libraries. There was another interface, using encryption, and bouncy castle libraries for that were installed on the JVM, which was preventing AS2 adapter to...
View ArticleRe: Delivery Created - Inspite of Delivery Block in Schedule Line
Hi Shankar, I've never faced this issue but there is a slight difference between Production and Test Environment. You might want to ask your basis to set Client Role in SCC4 to "Production" role in...
View ArticleCan anyone explain difference between SAP BW 7.3 and BW 7.4
1) Differences between SAP BW 7.3 and BW 7.42) SAP BW 7.4 features etc
View ArticleRe: How to read a PDF from an RFC and show it in a web page or external platform
Hi,Is this your custom table? Is it possible to store your pdf as base64 string in the table? In which format you have saved this currently?May be this may help you Regards,Alenlee MJ
View ArticleAdd message number to mail notification header (smartforms)
Hi all, i need to add message no to mail notification header on smartforms.like example : Solman Notification 123123 is notification number on created.can we do that on solution manager?
View ArticleCreate Webdynpro Application link on Portal
Hi All, I am new to webdynpro....i have created one Webdynpro application and just for sake of practice i want to link that application to the portal.Please let me know what is the prerequisites for...
View ArticleRe: Workflows getting struck after upgrade to 7.2
The CASE Branch is not able to resolve.... check: 1) Is there a branch available if none of the multiple conditions are met....that isthe "Others" branch2) Also check if there are any alpha numeric...
View ArticleRe: Login to BW and SAP retail
Hi JC, If you are using single sign-on then you don't need to login multiple times. You have to login once and then you can access all the systems you are authorized to use. In your previous project...
View ArticleRe: Delete Multiple Sub Assets ASSET_MASTERRECORD_MAINTENANCE
Hello Nabheet, Thanks for all the help. I guess this is the only solution left. I got the requirement modified because of a loophole I found in the requirement. So this question still needs another...
View Article